Air-cooled water chillers use finned condensers and fans for heat rejection, making them practical where cooling tower water is limited or installation needs to stay compact.
Air-Cooled Water Chiller selection notes
Review cooling capacity, inlet and outlet water temperature, chilled water flow, installation climate, voltage and maintenance access before choosing a model. AIM Refrigeration can help match the chiller table data to the real process load.
Air-Cooled Water Chiller Models
Compact AS series comparison for projects where cooling water is limited or where an independent heat-rejection system is preferred.
| Model | Capacity kW | Power | Total kW | Comp. kW | Tank L | Pipe | Pump kW | Flow L/min | Head m | Size mm |
|---|---|---|---|---|---|---|---|---|---|---|
| 1AS | 3 | 220V 1P | 1.27 | 0.75 | 30 | DN25 | 0.37 | 70 | 18 | 800 x 510 x 770 |
| 2AS | 6 | 220V 1P | 2.02 | 1.50 | 30 | DN25 | 0.37 | 70 | 18 | 800 x 510 x 770 |
| 3AS | 9 | 380V 3P | 2.92 | 2.25 | 50 | DN25 | 0.37 | 70 | 18 | 1125 x 560 x 1135 |
| 5AS | 15 | 380V 3P | 4.86 | 3.75 | 60 | DN25 | 0.37 | 70 | 18 | 1260 x 640 x 1425 |
| 8AS | 24 | 380V 3P | 8.42 | 6.00 | 120 | DN40 | 0.75 | 166 | 18 | 1530 x 775 x 1510 |
| 10AS | 30 | 380V 3P | 9.5 | 7.50 | 120 | DN40 | 0.75 | 166 | 18 | 1530 x 775 x 1510 |
| 12AS | 36 | 380V 3P | 11.42 | 9.00 | 120 | DN40 | 0.75 | 166 | 18 | 1530 x 775 x 1510 |
| 15AS | 45 | 380V 3P | 13.41 | 11.25 | 150 | DN50 | 1.5 | 166 | 20 | 1750 x 840 x 1705 |
| 20AS | 60 | 380V 3P | 18.92 | 15.00 | 270 | DN50 | 2.2 | 166 | 20 | 2000 x 920 x 1850 |
| 25AS | 75 | 380V 3P | 23.71 | 18.75 | 270 | DN50 | 2.2 | 166 | 20 | 2000 x 920 x 1850 |
| 30AS | 90 | 380V 3P | 29.08 | 22.5 | 400 | DN65 | 4 | 500 | 20 | 2370 x 960 x 1930 |
The table is a compact model selector. Final configuration may be adjusted according to refrigerant, voltage, ambient temperature, water condition and project requirements.
Need help choosing a Air-Cooled Water Chiller?
Send cooling load, water temperature target, installation country and operating schedule for model selection support.
Technical questions buyers ask before choosing Air-Cooled Water Chiller.
These points help overseas buyers compare capacity, condenser type, project data and equipment scope before requesting a quotation from AIM Refrigeration.
How should a buyer choose an industrial water chiller?
Selection should be based on cooling capacity, inlet and outlet water temperature, ambient temperature, operating hours, pump requirements, condenser type and power supply.
Is air-cooled or water-cooled better for a chiller?
Air-cooled chillers simplify installation where water is limited. Water-cooled chillers can be more efficient for larger plants when cooling tower water and maintenance are available.
Can chillers be used together with ice machines for concrete cooling?
Yes. Concrete cooling systems often combine chilled water, flake ice production, ice storage, delivery conveyors, weighing hoppers and batching plant control.